| No License or Inspection Required | Complies with the pressure vessel exemption inspection regulations established by the Industrial Safety Inspection Institute. |
|---|
| Fully Automatic Operation | Water supply, combustion, operation, and shutdown are all automatically controlled for easy operation. |
|---|
| High Efficiency & Energy Saving | Equipped with a high-performance burner and excellent overall design for high boiler efficiency. |
|---|
| High Quality Steam Supply | High-performance steam-water separator maintains excellent steam dryness. |
|---|
| Excellent Safety | Equipped with multiple safety devices including low water level control, safety valve, flame failure monitoring, and overheating protection. The system automatically shuts down in case of abnormal conditions to ensure operational safety. |
|---|
| Compact Size & Low Noise | Compact boiler design maximizes space utilization while maintaining low operating noise. |
|---|
| Professional Technology & Complete After-Sales Service | Provides steam application consultation, fast service response, and professional technical support. |
|---|
| Item / Model | Model | K-100M | K-200M | K-300M | K-500M |
|---|
| Type | --- | Multi-Tube Once-Through Steam Boiler |
|---|
| Total Heat Output | kg/hr | 53,900 | 107,800 | 167,100 | 269,500 |
|---|
| Equivalent Evaporation Capacity | kg/hr | 100 | 200 | 300 | 500 |
|---|
| Maximum Pressure | kg/cm²G | 7(0.687Mpa) | 10(0.980MPa) |
|---|
| Working Pressure | kg/cm²G | 3.5~6 | 5~9(0.490~0.883MPa) |
|---|
| Heating Surface Area | ㎡ | 2.2 | 4.5 | 4.5 | 4.9 |
|---|
| Control Method | Combustion | --- | ON–OFF | Three Position |
|---|
| Feed Water | --- | ON–OFF |
|---|
| Efficiency | % | 87 | 88 | 87 | 86 |
|---|
| Combustion Type | --- | Forced Draft Spray Combustion |
|---|
| Fuel Type | --- | Kerosene / Diesel Oil |
|---|
| Fuel Consumption | L/hr(kg/hr) | 7.5(6.0) | 14.9(11.8) | 22.6(17.9) | 38.1(30.1) |
|---|
| Power Supply | --- | AC200/220V 50/60Hz 3Ø |
|---|
| Power Consumption | kw | 0.4 | 0.6 | 0.9 | 1.6 |
|---|
| Dimensions | Length W | mm | 585 | 830 | 895 | 855 |
|---|
| Width D | 735 | 950 | 950 | 1,255 |
|---|
| Height H | 1590 | 1,945 | 1,945 | 2,050 |
|---|
| Weight | Boiler Body | Kg | 215 | 405 | 410 | 560 |
|---|
| Water Capacity (Standard Water Level) | 30 | 65 | 65 | 80 |
|---|
| Total Weight | 245 | 470 | 475 | 640 |
|---|
| External Connection Diameter | Steam Pipe | Diameter | 3/4 | 1 | | 1 1/4 |
|---|
| Water Supply Pipe | 1/2 | 3/4 |
|---|
| Fuel Pipe (Inlet) | 1/4 | 3/8 |
|---|
| Fuel Pipe (Return) | 1/4 | 1/4 |
|---|
| Bottom Drain Pipe | 1" |
|---|
| Safety Valve Outlet | 3/4 | 1 | | |
|---|
| Chimney (Inner Diameter) | Ømm | 150 | 200 | 200 | 250 |
|---|
| Power Cable | mm² | 2 |
|---|
Boiler efficiency test conditions are based on steam pressure of 5 kg/c㎡, feed water temperature of 20℃, combustion air temperature of 35℃, fuel calorific value of 8400 Kcal/L, specific gravity of 0.8, and natural gas (13A) low heating value of 9960 Kcal/Nm3.